Ideal kit for IAQ professionals, with a focus on air flow measurement. You will receive the testo 400 universal IAQ measuring instrument with intuitive measurement menus, one vane probe head (Ø 16 mm), one vane probe head (Ø 100 mm) and one high-precision humidity/temperature probe head – all three can be attached to the Bluetooth® handle supplied. For measurements at ceiling outlets, simply combine the 100 mm vane probe with the telescope (can be extended up to 1.0 m) and the 90° angle.
Measuring range | -40 to +150 °C |
---|---|
Accuracy | ±0.5 % of mv ±1 Digit (Remaining Range) ±0.4 °C ±1 Digit (+75 to +99.9 °C) ±0.2 °C ±1 Digit (-25 to +74.9 °C) ±0.4 °C ±1 Digit (-40 to -25.1 °C) |
Resolution | 0.1 °C |
Measuring range | -200 to +1370 °C |
---|---|
Accuracy | ±(0.3 °C + 0.1 % of mv) ±1 Digit |
Resolution | 0.1 °C |
Measuring range | 0 to +200 hPa |
---|---|
Accuracy | ±(0.1 hPa + 1.5 % of mv) ±1 Digit (25.001 to 200 hPa) ±(0.3 Pa + 1 % of mv) ±1 Digit (0 to 25 hPa) |
Resolution | 0.001 hPa |
Measuring range | 700 to 1100 hPa |
---|---|
Accuracy | ±3 hPa |
Resolution | 0.1 hPa |
Weight | 510 g (instrument) |
---|---|
Dimensions | 210 x 95 x 39 mm ((LxWxH)) |
Operating temperature | -5 to +45 °C |
Product-/housing material | Plastic |
Protection class | IP40 |
Connectable probes | 4 x digital Bluetooth® probe or testo Smart Probe; 2 x digital probe with fixed cable or temperature probe NTC with fixed cable (via Testo Universal Connector - TUC); 2 x temperature probe TC type K with fixed cable |
Product colour | black/orange |
Camera image size | Main camera: 8.0 MP; Front camera: 5.0 MP |
Battery life | approx. 10 hrs continuous operation |
Display type | 5.0" touch display, HD 1280*720 pixels, IPS (160 k) |
Power supply | Rechargeable li-ion battery (5550 mAh) |
Interface | Bluetooth®; USB; WLAN |
Memory | 2 GB; 1,000,000 measuring values |
Storage temperature | -20 to +60 °C |
*TUC connection (Testo Universal Connector): For the connection of fixed cable digital probes and NTC probes. |
Measuring range | -10 to +70 °C |
---|---|
Accuracy | ±1.8 °C |
Resolution | 0.1 °C |
Measuring range | 0.6 to 50 m/s |
---|---|
Accuracy | ±(0.2 m/s + 1 % of mv) (0.6 to +40 m/s) ±(0.2 m/s + 2 % of mv) (40.1 to 50 m/s) |
Resolution | 0.1 m/s |
Storage temperature | -20 to +60 °C |
---|---|
Weight | 425 g |
Dimensions | 790 x 50 x 40 mm |
Operating temperature | -5 to +50 °C |
Length probe shaft | 230 mm |
Diameter probe shaft | 16 mm |
Length telescope | 1,000 mm |
Probe head diameter | 16 mm |
Product colour | black/orange |
Battery type | 4 x type AA batteries |
Battery life | 70 h |
Data transfer | Bluetooth® |
Radio range | 20 m |
Measuring range | -20 to +70 °C |
---|---|
Accuracy | ±0.5 °C |
Resolution | 0.1 °C |
Measuring range | 0.3 to 35 m/s |
---|---|
Accuracy | ±(0.1 m/s + 1.5 % of mv) (0.3 to 20 m/s) ±(0.2 m/s + 1.5 % of mv) (20.01 to 35 m/s) |
Resolution | 0.01 m/s |
Storage temperature | -20 to +70 °C |
---|---|
Weight | 125 g |
Dimensions | 180 x 105 x 46 mm |
Operating temperature | -20 to +70 °C |
Probe head diameter | 100 mm |
Product colour | Black |
Measuring range | -20 to +70 °C |
---|---|
Accuracy | ±0.5 °C (Remaining Range) ±0.3 °C (+15 to +30 °C) |
Resolution | 0.01 °C |
Measuring range | 0 to 100 %RH |
---|---|
Accuracy | ±(0.6 %RH + 0.7 % of mv) (0 to 90 %RH) Hysteresis: ±0.4 %RH long-term stability: ±1 %RH / year ±0.03 %RH/K (k=1) ±(1.0 %RH + 0.7 % of mv) (90 to 100 %RH) |
Resolution | 0.01 %RH |
Storage temperature | -20 to +70 °C |
---|---|
Weight | 20 g |
Dimensions | 160 x 28 x 28 mm |
Operating temperature | -20 to +70 °C |
Diameter probe shaft | 12 mm |
Length probe shaft | 140 mm |
Product colour | Black |
Weight | 25 g |
---|---|
Dimensions | 65 x 65 x 15 mm |
Product colour | Black |
Weight | 2800 g |
---|---|
Dimensions | 520 x 410 x 160 mm LxWxH |
Product-/housing material | Plastic |
Product colour | Black |